Metering pump in use to deal with problems

When running dosing system should pay attention to what important matters? When running dosing system, pay attention to the following points: A. Dosing pressure B. Stroke frequency C. Suction height D. Altitude E. Corrosive chemicals When metering pump outlet at atmospheric pressure, is there any way to improve the pump double counting accuracy? Installing the valve spring at the metering pump discharge valve improves repeat metering accuracy, but the most effective improvement is the installation of a backpressure valve at the end of the line. How to adjust the back pressure valve? 1. Never exceed the maximum working pressure of the metering pump. 2. When the dosing pump has pressure on the suction side, the pressure on the discharge side of the pump must be at least 1 bar higher than the pressure on the suction side. How to choose the right pulse damper volume? By multiplying the metering capacity (ml) per stroke of the metering pump (ml) by 26, the minimum volume (ml) of the pulsation dampener required to reduce the 90% pulsation can be obtained. How to set the pressure relief valve? The pressure of the safety valve can be adjusted within the range of the rated working pressure of the metering pump. It is not allowed to exceed the maximum working pressure of the metering pump. The safety valve is designed to prevent over-pressurization of the metering pump. For example, if the maximum working pressure of the metering pump is 3 bar, the relief valve pressure should be set at 3 bar, or lower to ensure proper operation of the metering pump. Overpressure is one of the major causes of dosing pump damage. If the delivery of liquid is not water, how to calculate the suction height? Divide the metering pump's nominal aspiration height by the specific gravity of the metering liquid. Under what circumstances with self-irrigation suction? Self-priming aspiration can be applied if: 1.Measurement of liquid volatile; 2. Measuring the proportion of liquid larger; 3. When higher stroke frequency is required; 4. Metering pump work in high altitude areas; 5. In the field of application requires a larger tank, and rely on the self-priming pump is not feasible. Could you give me some advice on pump head selection? What are some common problems with chemical pump head / seal corrosion and should I avoid? The usual problem when it comes to metering pump heads is the presence of acid, chlorine, fluoride and hydrogen peroxide. Due to the different drug concentration and operating temperature, it is difficult to determine the specific pump head material. When measuring fluoride, we recommend using a Viton® sealed PVC pump head. For most chlorination applications, it is best to use an EPDM sealed NP (plexiglass) pump head. For the hydrogen peroxide mixture can only be measured PTFE PTFE sealed PTFE pump head or stainless steel pump head. Concentrated hydrochloric acid is usually measured Viton? Sealed plexiglass pump head. Concentrated sulfuric acid can be selected PTFE sealed PTFE pump head. Manufacturers of chemicals may give advice or consult ProMinent ™ chemical preservative charts to determine the compatibility of chemicals with contact materials. When measuring the liquid in the pump head, which factors must be considered? The main factors to be considered are the viscosity, specific gravity, vapor pressure and temperature of the liquid.